IPPIPSOPERATING INSTRUCTIONSwww.memmert.com | www.atmosafe.netPELTIER-COOLED INCUBATOR IPPPELTIER-COOLED INCUBATOR IPPSTORAGE COOLED INCUBATOR IPSSTOR
10 D24034 | Date 10/2014Construction and description2. Construction and description2.1 Construction1234 5 6178°C22.4TEMP°CSet 37.0TIMER30m04hEnde 2
D24034 | Date 10/2014 11Construction and description2.2 DescriptionThe appliance can heat the working chamber up to 70 °C (IPP) or 45 °C (IPS) and c
12 D24034 | Date 10/2014Construction and description2.5.2 Ethernet interfaceThe Ethernet interface is intended for appliances which meet the requirem
D24034 | Date 10/2014 13Construction and description2.7 Technical dataAppliance IPP IPSAppliance size 30 55 110 260 750 260 750Appliance width DAppl
14 D24034 | Date 10/2014Construction and descriptionDAFGC56EB90°C22.4TEMP°CSet 37.0TIMER30m04hEnde 23.Nov 13:30LICHT%100Fig. 5 Dimensions2.8 Applie
D24034 | Date 10/2014 15Construction and description2.10 Ambient conditions►The appliance may only be used in enclosed areas and under the followi
16 D24034 | Date 10/2014Delivery, transport and setting up3. Delivery, transport and setting up3.1 Safety regulationsWarning!Because of the heavy wei
D24034 | Date 10/2014 17Delivery, transport and setting up3.2 DeliveryThe appliance is packed in cardboard and is delivered on a wooden palette.3.3
18 D24034 | Date 10/2014Delivery, transport and setting up3.6 Setting upWarning!Due to its centre of gravity, the appliance can fall over to the fron
D24034 | Date 10/2014 19Delivery, transport and setting up3.6.2 Installation optionsSetting up Comments Suitable for appliance size ...30 55 110 260
Manufacturer and customer serviceMemmert GmbH + Co. KGWilli Memmert Straße 90-96D-91186 BüchenbachDeutschlandPhone: +49 (0)9122 925-0Fax: +49 (0)9
20 D24034 | Date 10/2014Delivery, transport and setting up3.6.3 Tilt protectionAttach the appliance to a wall with the tilt protection. The tilt prot
D24034 | Date 10/2014 21Putting into operation4. Putting into operationCaution:The first time the appliance is operated, it must not be left unatten
22 D24034 | Date 10/2014Operation and control5. Operation and control5.1 Operating personnelThe appliance may only be operated by persons who are of
D24034 | Date 10/2014 23Operation and control5.3 Loading the applianceWarning!When loading the appliance with an unsuitable load, poisonous or explo
24 D24034 | Date 10/2014Operation and control5.4 Operating the appliance5.4.1 ControlCOCKPITIn manual operation, the desired parameters are entered a
D24034 | Date 10/2014 25Operation and control3. Save the set value by pressing the confir-mation key. The display returns to normal and the applian
26 D24034 | Date 10/2014Operation and control2. Turn the turn control until the desired duration is displayed – in this example 4 hours 30 minutes. T
D24034 | Date 10/2014 27Operation and control5.5 Temperature monitoring The monitoring temperature of the electronic temperature monitoring is mea
28 D24034 | Date 10/2014Malfunctions, warning and error messages6. Malfunctions, warning and error messagesWarning!After removing covers, live parts
D24034 | Date 10/2014 29Malfunctions, warning and error messages Error description Cause of errors Rectifying errors SeeError message E-3 in the t
D24034 | Date 10/2014 3About this manual About this manualPurpose and target groupThis manual describes the assembly, function, transport and operat
30 D24034 | Date 10/2014Menu mode7. Menu modeIn menu mode, you can make basic settings as well as adjust appliance parameters.Caution:Before changing
D24034 | Date 10/2014 31Menu mode7.2 Basic operation in menu mode using the example of language selectionIn general, all settings in menu mode are d
32 D24034 | Date 10/2014Menu modeAll other settings can be made accordingly. The settings possible are described in the follow-ing sections. If no ne
D24034 | Date 10/2014 33Menu mode1. Activate the SETUP display. The entry IP address is automatically highlighted.SETUPBalancePROGRAMTIMEUSER IDPROT
34 D24034 | Date 10/2014Menu mode7.3.2 UnitHere, you can choose whether the temperature is displayed in °C or °F.7.3.3 Timer modeHere, you can choose
D24034 | Date 10/2014 35Menu mode7.3.6 Remote control In the setup entry Remote control, you can set whether the appliance should be controlled vi
36 D24034 | Date 10/2014Menu mode3. Accept the selection by pressing the confirmation key. Hauptschalter>Zu der Typenbezeichnung gibt es momentan
D24034 | Date 10/2014 37Menu mode7.5 CalibrationThe appliances are temperature calibrated and adjusted at the factory. In case readjustment should b
38 D24034 | Date 10/2014Menu mode3. With the turn control, set the calibration temperature Cal2 to 30 °C. Hauptschalter>Zu der Typenbezeichnung gi
D24034 | Date 10/2014 39Maintenance and service8. Maintenance and service8.1 CleaningWarning!Danger due to electric shock. Before doing any mainten
4 D24034 | Date 10/2014Contents1. For your Safety 61.1 Terms and signs used...
40 D24034 | Date 10/2014Maintenance and service8.2 Regular maintenanceOnce a year, grease the moving parts of the doors (hinges and lock) with thin s
D24034 | Date 10/2014 41Storage and disposal9. Storage and disposal9.1 StorageThe appliance may only be stored under the following conditions:►in a
42 D24034 | Date 10/2014Index IndexAAccessories 15Activation key 24Adjustment 37Ambient conditions 14Ambient temperature 14Appliance error 28A
06/15/2012HPP/IPPplus EnglishD24029Memmert GmbH + Co. KGWilli-Memmert-Straße 90-96 | D-91186 BüchenbachTel. +49 9122 925-0 | Fax +49 9122 14585E-Mail:
D24034 | Date 10/2014 5Contents5. Operation and control 225.1 Operating personnel...
6 D24034 | Date 10/2014For your Safety1. For your Safety1.1 Terms and signs usedIn this manual and on the appliance itself, certain common terms and
D24034 | Date 10/2014 7For your Safety1.2 Product safety and dangersThe appliances described in this manual are technically sophisticated, manufactu
8 D24034 | Date 10/2014For your Safety1.4 Responsibility of the ownerThe owner of the appliance►is responsible for the flawless condition of the appl
D24034 | Date 10/2014 9For your Safety1.7 Behaviour in case of malfunctions and irregularitiesThe appliance may only be used in a flawless condition
Kommentare zu diesen Handbüchern